Datalogic Skorpio X4 Wavelink TE v7.3.299 installation program or new TE?

$
0
0

Waiting for newer version of the Wavelink Telnet CE for Datalogic X4 CE7 Devices (now only v7.3.308) , I noticed that the v7.3.299 is already installed on the X4. Is there any possibility to find somewhere the installation program of this version?

 

 

As with the Datalogic Skorpio X3 the newer v7.3.302 had problems at usage of Function keys but installing the older v7.3.299  the problem was fixed automatically , the same i believe for all problems I have with the Wavelink TE at Skorpio X4 . I think there are some problems with the only version, which displays the letters in wrong way at menus and makes different the display for some of the screens at client's menu. Unfortunately ,there is no other version in case for me to check and use at Skorpio X4 .


Wavelink Android Version

$
0
0

Sehr geehrte Damen und Herren,

 

gibt es für die Wavelink Android Version eine Konfiguratorsoftware ? Ich würde gerne die Wavelink Tastatur deaktivieren wollen und eine spezielle Konfiguration erstellen.

 

Mit freundlichen Grüßen

 

Daniel Kortas

TelnetCE/Data Wedge does not decode GS1-128 symbology. Symbol MC92N0 (Android Kit Kat)

$
0
0

I am having an issue where while using the TelnetCE application on MC92N0 devices running android it fails to decode GS1 barcodes. The scan settings for TelnetCE are manipulated in the Datawedge settings on the device and I have enabled GS1 symbology in the correct location. However when I attempt to scan the GS1 barcode it does not decode it. If I run DWdemo app on the device and scan the GS1 barcode it decodes correctly. So the issue seems to be isolated to TelnetCE.

Configuration Function Key F5 and F6 to TE VT220

$
0
0

Anyone knowthe configuration ofkeysF5andF6function inVT220emulation?


I have a customer usgin SAP VT220 emulation.

 

 

I triedthe settings below,butit did not work

F5 - 3F00:\3F00\000D

F6 - 4000:\0336\000D

 


Enter Key and field exit for As400 emulator

$
0
0

Hi all

i need to use DATALOGIC FALCON X3 connected to an As400 via 5250 emulator .. i don't understand how to configure keyboard key (not virtual keyboard) so that i can emulate "ENTER" and "Exit fields"  keys  tipical for As400

Thanks in advance

Setting the answer back on VT emulation CE

$
0
0

Hello,

 

I am trying to set the answer back onto Wavelink Terminal emulation CE , but without success.

 

The name of the unit is talking to a VT200 WMS server and needs the name to identify it to the system.

 

I am setting    DESMTM030 .  But cant work out the format to set in the product Configuration tool.. Setting in Emulation Paramaters > emulation > VT & HP > common > VT new answer back.

 

Thanks for your help.

Symbol MC9090 download version for telnetce (wavelink)

$
0
0

What manufacturer should I choose for download?  Neither Motorola or Symbol is listed.

cn51 does not read barcode if auto enter defined in postamble (\r)

$
0
0

Hello,

 

One of our customer has been bought your universal terminal emulation license for Intermec CN51.They have approx. 80 devices on their location.

 

They would like to connect their SAP system via emulation.Their operation is working without autoenter in postamble.But the barcode data is not shown on the screen when we read a barcode if we add \r to thepostamble section.

 

How can we solve this problem ?

 

TElnet version is 7.3.225.

Please reply asap.


SCRIPT PROBLEM ABOUT RFID

$
0
0

I’m a programmer who is working on your Wavelink Telnet CE product and I would to ask you about a problem in scripting code.

 

My customer own some Motorola MC319Z handhelds and asked me to configure a connection to their As400 and read some RFID Tags and put the datas in a blank field of their program.

 

I did the connection without any problem, as a 3477-FC emulator and entered in the emulation parameters to enable RFID functions, in ENABLE RFID key with Yes, in ENABLE KEY with <0x79> the F10 key in hexadecimal, in INSERT MODE with Auto-Detect, and USE TRIGGER with Yes.

 

I tried using it and when I arrive at the right screen of the program I press F10 on the keyboard of the handheld (not the keyboard of the emulator) and RFID start to read when I push the handheld read button, passing to my screen the tags read. It works correctly!

 

I also tried to create a script that, when reached the right screen of the program, it press automatically F10 using the code KEYPRESS_KEY <0x79> my F10 key but, it don’t works, this don’t enable the RFID reader.

 

When I did it manually it works perfectly and I receive a message on the screen that told me the number of tags read and put the tags on the field I use, but if I try to use the script, when KEYPRESS-KEY work, it do only a beep but no one message about RFID enable and create problems about the use of the emulator keyboard.

 

My script is a simple:

 

Script( RFID_MAN )

Profile( As400 )

Activate( From_Menu )

    Keypress_Key( 0x79 )

    Return

 

But it don’t press the F10 like I could do on the handheld keyboard. There’s something wrong in my code?

I would to enable RFID reader by script code and after the tags read end disable it.

 

Thanks for all and I hope you can help me as soon as possible.

 

Cordially

SSH support not working after cold boot

$
0
0

We have a Motorola MC9190 with Wavelink installed and I have installed the SSH support for it but after every cold boot I lose the option for SSH. Anyone know who to make this stick after a cold boot?

Scan Handler (Enter after barcode scan) not working

$
0
0

Hello,

 

I'm having problems with a Motorla scanner and Wavelink.

Everything (i need) that is configured in Emulation Parameters works, but the only thing that does not work is a "return" on barcode scan (Scan Handler).

My Wavelink version is TelnetCE 7.2.00 and i have a licence for VTHP.

 

29-1-2015 12-08-22.jpg

 

I have also tried to use A(0)[A\\0D] but that does not work either.

 

29-1-2015 12-43-29.jpg

The manual found on this page does not help either:

https://community.landesk.com/support/docs/29959

 

Is this a Wavelink version problem? Or am i doing something else wrong?

 

Scan Terminator is also \0D:

 

29-1-2015 12-46-31.jpg

 

I have re-installed the Wavelink software on the Scanner, but that didn't help either.

 

Does anyone have any idea that i'm doing wrong?

 

The scanner is a Motorola MC9090 with WIndows Mobile 5.1

 

Thanks in advance!

 

Greetings,

 

Zarko

Wavelink TE for the Motorola (Symbol) MC3200 CE 7. What versions are pre-licensed?

$
0
0

Hello.

Could you provide information about Wavelink TE versions which are pre-licensed for Motorola (Symbol) MC3200 CE 7 (MC32N0R).

Wavelink TN Client 4-in-1 + Annual Maintenance

$
0
0

We have sold the above to a client who is offshore and loading on Zebra MC55 terminals. They appear to have loaded the licences incorrectly and, after contacting us, they have now tried doing it in the correct order, but it is not allowing them to do it. Is there any way that the registering of the licences on the devices can be cancelled so that they can now start the licencing process on the devices from scratch. I can forward the serial numbers and authorization codes. Your assistance would be appreciated.

How can you avoid this?

$
0
0

Using our current WT4090 Wavelink config files, the WT41N0 asks the user to reboot the terminal to change the taskbar state.

We don’t want the users to make this choice.  If they choose no, then Wavelink does not go into Kiosk mode.  (Taskbar is unlocked)

Is there a way to update the config files so that a reboot is not necessary, have the device reboot automatically or as a last resort not attempt to lock the taskbar (so the popup does not appear)?

Untitled.png

 

platform not support error

$
0
0

Hello,

I have MC3200 Android Terminals,

 

I bought Velocity version TE. But when I want to install MC3200 Terminals, I get the message in the picture

IMG_3496.JPG


How to activate full screen in Wavelink TE client Windows

$
0
0

Hello,

 

how do i get rid of these bars? Title bar and Info bar at the bottom?

I'm using Wavelink TE 7.3.299 on Windows 7/8.1

Telnet not responding after "Networ Out-of-range"

$
0
0

Hi all,

 

we have recently faced issue with our TelnetCE that we are using on Datalogic barcode scanners. Issue is as follow:

when we are using WEB emulation in TelnetCE and we are walking inside our manufacturing area we are receiving "Network Out-of-range" popup when we are switching from one access point to another. This message is displayed for 1-2 seconds and in most cases when it is gone we can continue our work in the system. Unfortunately sometimes when "Network Out-of-range" message is gone, scanner is becoming frozen - we are trying to click anything in the system but we don't get any response and when we are trying to refresh the page in TelnetCE we are receiving "web page unavailable". Then if we will try to disconnect session and reconnect again we are once again receiving "web page unavailable" (but we have good connection as signal indicator is showing full, green signal strength). The only way to get scanner working is to reboot it.

 

We have already executed several activities to solve the issue but nothing is helping:

- we have updated firmware on the scanners to latest version

- we have executed wifi audit to double check that this is not a network issue

- we have changed and tested several settings in WiFi card configuration (in Summit Configuration Utility) to limit the number of situation when scanner is moving between access points.

- we have also disabled "Network support" option in Telnet configuration (section "Emulation"->"Network") but this change is only not displaying popup - instead of it we have progress bar that is loading and then after several seconds we have "frozen scanner"

 

So after all those actions we know that TelnetCE is sometimes hanging up when it is loosing network connection. As we have wireless devices we will never get rid of situation when devices are moving between access points or when they are travelling in areas where there is no WiFi signal, so now we would like to configure Telnet to work stable in those situations.


Does anyone faced same or similar issues? Or does anyone have any ideas what more we can change to get rid of "frozen scanners"?

 

Thanks for any reply!

Access to printer on Avery Pathfinder 6057

$
0
0

Hello,

we are currently testing Wavelink TE on an Avery Pathfinder 6057 and experiencing an issue while printing through ANSI codes.

The print job get sent to the terminal and a black box "Printing" appears; however no output goes to the printer.

The printer is defined as "PATHFINDER" connected to port COM1: but I don't know if this setting is correct; however the same file when sent via FTP to a specific folder on the device gets printed.

Is there a way to have Wavelink write the print data received to a folder rather than send it to a COM port?

why doesent SSH connection close on disconnect

$
0
0

Im running Velocity 2.0.2 and connecting to a Unix Server with ssh. The program does auto-login fine, however when I log off the server I get a blank screen until I hit a key. At that point I get an error - "Connection Lost" -Cannot access a disposed object. Object name 'ShellStream' 

 

I have to hit OK and it takes me back to the start up screen where my host profiles are shown. The only way I can exit the program is to actually exit out of the app the Android way.  I want the program to simply close once I log off. Is that possible?

How to take over a Wavelink configuration

$
0
0

Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via Active Sync) to another MC9100 but that don't work. If I looked in the Termcfg.bin I didn't find my configuration profile.

In which file is the configured profile from my Wavelink Telnet (Version 7.3.40) saved?

 

Another possibiltiy to take over the profile should be the Wavelink TelnetCE Configuration Utility but I can't find a download. Is this software only available for

maintenance agreement?

 

I hope you can help me :-)

Thanky You

 

Olaf