Quantcast
Channel: Ivanti User Community : Popular Discussions - Terminal Emulation (Powered by Wavelink)
Viewing all 8066 articles
Browse latest View live

Sesion VT220 Disconnectd

$
0
0

Hi

 

 

I am using theTelnetVT220typeequipmentv7.0.133MotorolaMC9190andMC9090.

The problemI haveis that thesessions are disconnectedaftera consultation, or to switch to anotheraccess point.

 

Thesecurity ofWLANisWPA2-AES

Sincethe wirelessclientwas updatedMC9000andSite Surveywas conductedandWLANseems fine.

 

Any recommendationsto fix this?


Printing from as400 through telnetce(Version7.3.028).

$
0
0

I have installed telnetce(Version 7.3.028) in a DATALOGIC elf PDA and I am able to connect to AS400 terminal through telnetce(using the emulation IBM-5251-11). I have paired a bluetooth printer on 'COM6' . Need to get print from AS400 to bluetooth printer.

 

But the output is not getting printed on printer.

 

Kindly guide me.

How to take over a Wavelink configuration

$
0
0

Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via Active Sync) to another MC9100 but that don't work. If I looked in the Termcfg.bin I didn't find my configuration profile.

In which file is the configured profile from my Wavelink Telnet (Version 7.3.40) saved?

 

Another possibiltiy to take over the profile should be the Wavelink TelnetCE Configuration Utility but I can't find a download. Is this software only available for

maintenance agreement?

 

I hope you can help me :-)

Thanky You

 

Olaf

How I replace GS (Group Separator) from GS1-128 by "]" character ?

$
0
0

I need to replace a <GS> (group separator) when I scan a GS1-128 barcode by a "]" character. How can I do that using terminal config from Wavelink Industrial Browser?

Scan Handler - How to remove barcode characters after the first 35

$
0
0

What does the formula look like?

Connection Reset by peer.

$
0
0

We are using Motorola VC5090(CE5.0) and MC3190(CE6.0) at warehouse, through Wavelink 7.3, we connected to end user Telnet SSH Server

 

We discover after a certain time, the packer who is currently working and using MC3190, the wavelink clients would "jump out" and the messages prompt shown "connection reset by peer", it cannot recover, it is need to relogin again. So, it got annoying and heavy complain on us

 

 

Under the same network, VC5090 is good and no disconnected problems. We go through the network packages by Wireshark and found the followings.

 

  • MC3190 is always retransmitted error and it is only using TCP package to transmit.
  • VC5090 is smooth and no error packages, it can using SSHv2 package to transmit

 

 

 

1) How can we avoid the messages jump out and disconnect which is "Connect reset by peer" at MC3190?

2) Can we setup on MC3190 to transmit the packages by SSHv2 just like VC5090

 

We got a long complain from end user, look forward for kindly technical expert to help us on this, really thank a lot.

VC5090.JPGMC3190.JPG

 

Regards,

William

Does Wavelink TelnetCE support Chinese (We are using a Motorola MC9190-G gun)?

$
0
0

Does Wavelink TelnetCE support Chinese (We are using a Motorola MC9190-G gun)?

 

When We look for Chinese in the localization configuration, We do not find the Chinese option.

 

¿Should our MC9190-G have a Chinese-localized WinCE for the TelnetCE software to support Chinese?

 

 

Please advice.

Remap function keys

$
0
0

Hi,

 

I'm trying to remap F1 to [ALT][F1] with the Wavelink TE Android's version for a Panasonic FZ-A1, as far as I know F1 stands for 3B00 , but I don't know wich scape secunce stands for [ALT] key, and hoy to concatenate it with the [F1].

 

¿Does any of you has an idea about how to solve it?

 

 

Thanks in advace,


WT4100 StartUp Problem

$
0
0

We just got new WT4100 from our distributor. Using with TelnetCE at version 7.3.144 (5250 and WT100 sessions). The problem we are facing is that after boot an aoutostrup applican  (WT41NOSTARTUP) is automatically launced by the system. This application is undesired and in conflict wiith the one (TelnetCE) we configured to startup.

 

The main question is how to remove the WT41NOSTARTUP application from startup. We already checked that the application is not defined into the startup folder. Also can see that the WT41NOSTARTUP has a shortcut onto the desktop. If we remove from the desktop at next boot it reappers.

 

Regard Antonio.

Wavelink TelnetCE 73197 Display Language - UTF8

$
0
0

Hello.

I have Motorola MC3190 and TelnetCE 73197. I need select UTF8 in "Display Language". It is demand for correct display Russian language in the programm. I do not see UTF8 in list "Display Language".

How i do it?

Best regards,

   Andrey.

Configuration Function Key F5 and F6 to TE VT220

$
0
0

Anyone knowthe configuration ofkeysF5andF6function inVT220emulation?


I have a customer usgin SAP VT220 emulation.

 

 

I triedthe settings below,butit did not work

F5 - 3F00:\3F00\000D

F6 - 4000:\0336\000D

 


Trimming of prefix while scanning

$
0
0


Hi there,

 

We are using Wavelink Emulation Parameters to config the handheld (Honeywell) to scan barcode.

 

The challenge I'm encountering is, while scanning barcodes, I will need to trim off the prefix (can be the first or first two characters).  Is there anyway i can configure the params in the scan handler that by press a function key or scanning a separate barcode to instruct the scanner trim off the characters?

 

Speaking to my local vendor, the best they could do is to trim of the prefix by default, which wouldnt work for me.

 

Appreciate any advice and thanks in advance.

 

 

regards,

Chong Fu

Function keys with WT41N0 Telnet CE 7.3.192 VT220 emulation

$
0
0

Hi i'm having difficulties using function keys with Motorola WT41N0 Telnet CE 7.3.192 and VT200 emulation. Random charachtes or error message key not recognized is diplayed if i'm trying to use Function keys (F1; F2 etc.) Any ideas?

WT41N0 TE Client SSH connection error: disconnected: no supported authentication methods available

$
0
0

The attached screenshot shows the SSH Client Fatal Error message from the title of this question.

TelnetCE for MC3190-S

$
0
0

Hello Community,

 

I've a bunch of MC3190-S (not guns). Please suggest me where to buy Wavelink TelnetCE for this terminal.

Directly from Motorola or from Wavelink?

I've found document on motorola website with part numbers of wavelink telnetce.

Document says that SWE-82990-01 is license 2-in-1 for all device types.

But this site http://www.barcodediscount.com/catalog/symbol/part-swe-82990-01.htm says the following:

Symbol SWE-82990-01

TN Client (Active Sync) for MC55, MC65, MC70, MC75, ES400 and ET1, VT/HP Emulation.

 

I'm totally confused. Will this part number fit MC3910-S ?

Thanks a lot,

Alex.


MC92N0 CE7.0 - TE ver 7.3.196 Keypad Problems

$
0
0

Hi, I have a problem using the TE 7.3.196 on a MC92N0 CE7 OEM version 00.33.06.

When I install the client for the first time the keypad works good, ie pressing the combo BLUE + ENTER the client produce the 000A scancode.

If a reboot the device the client is still configured but the keypad layout seems to be different, infact if I press BLUE + ENTER I get the scancode 000D instead of 000A.

 

Do you have any reported problems regarding this issue?

 

Thanks in advance

Mirko Marraro

Motorola MC9190 Chinese letters in Wavelink 5555 emulation

$
0
0

We use on a MC9190 the wavelink TelnetCE version 7.0.147. For our chinese colleagues I we use the emulation 5555-B01 to display also chinese letters.

Our problem is, that only a part of the chinese letters we have to display really are displayed. It depands from the selected font what happen with the other letters.

With some fonts the not displayed letters just are replaced with empty boxes. Some fonts just display a blank space.

How to solve this issue.

The operation system is a Windows CE in chinese.

Honeywell Captuvo SL62 and Wavelink Terminal CE

$
0
0

Hi,

I am testing Ipad mini 3 LTE with Honeywell Captuvo SL62. When I push a scanning button the scanner beam doesn't appear. Is the latest Wavelink for IOS fully supporting Captuvo SL62 or maybe I am missing something in Ipad or Terminal CE configuration?

 

Best Regards,

Jacek

SAP TURKISH CHARACTER PROBLEM

$
0
0

I solved this problem. When I change WEB Engin Value Enhanced--> Standart, this problem solved.

------------------

 

Dear All,

 

I cant display Turkish Character in Industrial Browser (SAP).

 

I should change which parameters.

 

Could you see attached file display copy.

Regards,

Emre20150108_145654.jpg

Motorola WT41N0 scanner with new Telnet Emulation version 7.3.153 problem

$
0
0

Dear colleagues,

 

I have problem with new demo Motorola Device Mobile Terminal WT41N0 (Windows CE 7.0)  with new vesion 7.3.153 of Wavelink Telnet emulation.I can not be able to scann when I am in Telnet emulation.The scanner is working in Windows normaly but when I am in Telnet it is just not working proparly.The scanner have scanner lane but it is not giving me any resault of scanning.please if somebody have some idea let me know.

 

Thank you very much.

Viewing all 8066 articles
Browse latest View live