Cannot get script working (multiple conditions)

$
0
0

Hi there,

 

I kindly ask you for some help because I'm stuck on a script for a customer.

 

My conditions work fine when alone, everytime I try to combine my conditions, i won't have any output when scanning (bulding the script returns no error).

Do you have an idea of what I'm doing wrong please ?

 

Device : MC92 CE, using TNCE v7.3.252

 

Thank you,

Nicolas

 

 

Script( KE1_REC )

String( sBarcode )

String( NewString )

Number( nBarcode )

Activate( On_Input, sBarcode, nBarcode )

    Comment: :  If(Boolean_And( String_Equal( Get_Screen_Text( 1, 1 ), "KE1 REC", 7, FALSE ),String_Equal( Get_Screen_Text( 4, 1 ), "LPN:", 4, FALSE ),Number_Equal(nBarcode, Get_Scan_Type_Value("QR CODE"))))

   If( String_Equal( Get_Screen_Text( 1, 1 ), "KE1 REC", 7, FALSE ) )

    If( String_Equal( Get_Screen_Text( 4, 1 ), "LPN:", 4, FALSE ) )

     If( Number_Equal( nBarcode, Get_Scan_Type_Value( "QR CODE" ) ) )

        NewString = String_Middle( sBarcode, 2, 18 )

        Keypress_String( NewString )

        Keypress_Key( "VT100", "Enter" )

        NewString = String_Middle( sBarcode, 30, 6 )

        Keypress_String( NewString )

        Keypress_Key( "VT100", "Enter" )

        NewString = String_Middle( sBarcode, 38, 10 )

        Keypress_String( NewString )

        Keypress_Key( "VT100", "Enter" )

        NewString = String_Middle( sBarcode, 50, 5 )

        Keypress_String( NewString )

        Keypress_Key( "VT100", "Enter" )

End_If

End_If

    Else

        Scan_String( sBarcode, nBarcode )

    End_If

    Return


Remap function keys

$
0
0

Hi,

 

I'm trying to remap F1 to [ALT][F1] with the Wavelink TE Android's version for a Panasonic FZ-A1, as far as I know F1 stands for 3B00 , but I don't know wich scape secunce stands for [ALT] key, and hoy to concatenate it with the [F1].

 

¿Does any of you has an idea about how to solve it?

 

 

Thanks in advace,

Auto login password

$
0
0

I tried to make auto login in TE 7.3 on motorola mc9190 but the process stop at password and I need to enter it manually. The user name and the command that came after passing automatically, only the password needed to enter manually.

Configuration Function Key F5 and F6 to TE VT220

$
0
0

Anyone knowthe configuration ofkeysF5andF6function inVT220emulation?


I have a customer usgin SAP VT220 emulation.

 

 

I triedthe settings below,butit did not work

F5 - 3F00:\3F00\000D

F6 - 4000:\0336\000D

 


TelnetCE - make a macro

$
0
0

Hello there,

I'm using TelnetCE 7366 and I'm trying to exit the emulation (5250 or VT) with a datalogic Skorpio keybord. I tried FN ALT x but it doesn't works. I have to make a specific macro? if so how do that ?

Thanks in advance for your help.

Ctrl 2 as Barcode or F2 as Barcode?

$
0
0

Hallo,

 

i want to print a funktional key as Barcode.

We use Motorola 9090 with 28 keys and Wavelink TelnetCE.

Our Users Need to press "ctrl 2" 500 times a day. I want to solve this with a Barcode. Does anybody know how to do this?

Our emulationtype is XTERM.

 

THX

Client SSH Support for ARM and X86 based Mobile Devices v2.00.06 and .04

$
0
0

Hi,

 

I'm testing MX7 Tecton with Wavelink TE v. 7.3.188 and when I connect to the server using SSH and run 'cat' command with large file then emulator hangs up and has to closed. The issue only occurs when I use Client SSH v2.00.06 and .04 when I use version v1.10-06 then everything is ok. Do you what might be causing the issue?

How to display Telnet Negotiation String on screen

$
0
0

Hi,

 

Is there a way to display telnet negotiation string on screen on Zebra MC9190G mobile device ?

If you see file profiles.dat there is parameter telnet_negotiation_string.

 

Idea is to display value of telnet_negotiation_string on first screen when session connects.

Can it be done using key combination (as displaying MAC and IP address using key combination <Alt>+P)?

 

Version of TE is 7.3.

Emulation type is VT100.

 

BR,

Milorad Mezej


How to have loudly sound on MC3190?

$
0
0

Hello,

on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse

 

we need to know how we can set correctly TelnetCE to have a very heavy sound

 

thanks

 

Sebastien

Automatic carriage return with wavelink

$
0
0

Hello,

I use the wavelink TelnetCE Version 7.0.01 on a Windows CE (Motorola MC9100). Is there an option in the wavelink software for an automatic carriage return? I think about a putty client. With a putty client I can change the size from the terminal windows and at the end of a line putty makes an automaticc carriage return.

 

Is that also possible with wavelink TelnetCE?

 

Thank you for any help

 

Olaf

How do I use F12 key in Wavelink on a WT4090

$
0
0

How do I use F12 key in Wavelink on a WT4090.

 

Only have F1-F10 keys.

Scan Handler (Enter after barcode scan) not working

$
0
0

Hello,

 

I'm having problems with a Motorla scanner and Wavelink.

Everything (i need) that is configured in Emulation Parameters works, but the only thing that does not work is a "return" on barcode scan (Scan Handler).

My Wavelink version is TelnetCE 7.2.00 and i have a licence for VTHP.

 

29-1-2015 12-08-22.jpg

 

I have also tried to use A(0)[A\\0D] but that does not work either.

 

29-1-2015 12-43-29.jpg

The manual found on this page does not help either:

https://community.landesk.com/support/docs/29959

 

Is this a Wavelink version problem? Or am i doing something else wrong?

 

Scan Terminator is also \0D:

 

29-1-2015 12-46-31.jpg

 

I have re-installed the Wavelink software on the Scanner, but that didn't help either.

 

Does anyone have any idea that i'm doing wrong?

 

The scanner is a Motorola MC9090 with WIndows Mobile 5.1

 

Thanks in advance!

 

Greetings,

 

Zarko

Licence Information for MC9200

$
0
0

Hi I am using below configuration and RF guns

Model, P/N:       MC9200

Wave link version: MOT_MC92_N0_WM65 Telnet CE (WM6.5)  (I tried with 7.0 but not able to host it on RF gun Due to compatibility issue let me know if I need to use any other)

Brief Description:  

  We are trying to use these guns in integration with SAP server.We have published services (address: in screen shot) for SAP transaction which are going to access from RF guns.

 

  • Need to know the exact information about license we will required.
  • Which License from wave link ?
  • Do we need to have Avalanche or Telnet will suffice our need.
  • What is OEM license we need it ?
  • How to procure them?
  • where and how install them?

Function Keys not working on MC3190M

$
0
0

Function Keys not working on MC3190

How to make it works.

Adding extra digit when scanning code 39

$
0
0

Hello,

We have TC70’s that add digits to code 39 barcodes, using Terminal Emulation.

The fix I have found for this is. When I go into Datawedge - Profile0 - Decoder Params – Code 39 – Verify Check Digit I check this box, go back into TE and the barcode scans fine without adding the extra digit.

When I restart the scanner and go back to Datawedge the Verify Check Digit box is unchecked when scanning a code 39 barcode again it adds the extra digit again.

I have been told this is not a data wedge issue and is TE related.

The only thing that I can see that would help or add a digit in TE would be the Scanner settings but we don’t make any settings changes in the group.

Running TC70 scanner with Android 4.4.3, TE version 2.0.18.4977, Datawedge Version 4.0.5


Esc key not functioning in terminal session

$
0
0

Hello,

 

We recently received several new devices with Windows Mobile 6.  With these new devices I am unable to get the Esc key to register when in an active Terminal session.  I brought up the keyboard test,  and no value is returned when I press the Esc key.  Regular letter and number keys are returning the proper codes.  If I press the Esc key on the emulation keyboard the proper value does show up.

 

I have gone over and over the configuration settings without success.  I've compared the working device settings to our new device settings and can't find any differences.  It seems like I must be missing something simple.  Any assistance is much appreciated.

 

Device:  Motorola VC6090

Wavelink TelnetCE version:  7.3.79

Wavelink Telnet CE - How to send Function key by barcode scan (5250 emulation)

$
0
0

How can I setup Wavelink TelnetCE v. 7.0.108  (5250) to send F12 key when I scan a F12 barcode for exemple ?

Wavelink F12 not working, 5250 emulation, MC92N0.

$
0
0

Hi,

 

we cannot get the F12 key to work using 5250 emulation with ZEBRA MC92N0 CE7.O. When we try to get F12 to work we get an @ symbol, so we added the key macro 0040:\E055 to swap for the F12 key.

 

Now when we try the @ symbol does not appear but F12 does not function either?

 

Any help would be much appreciated.

Scanner not returning data

$
0
0

I've been having some occasional trouble with the Wavelink Industrial Browser on some Datalogic Falcon X3s. (Both the Falcon X3 and Falcon X3+)
The IB shows the web page correctly, but when a scan is attempted, it seems like it reads the barcode (IE, the laser turns off), but there is no confirmation beep, and the data is not returned to the input box on the screen.
I've already confirmed that the scanning functionality works fine outside of Wavelink. Dropping back to Windows, they can scan text to Notes just fine.

 

I found this article in the knowledge base, but these settings don't seem to have made a difference.
Scanner wont input data on CI70 Device Using TelnetCE.

 

Anyone else run into this issue before?

Wavelink browser to decode EAN128 Barcode

$
0
0

Using wavelink TE(Browser) on MC9190,When to read the EAN128 barcode,some space will appear in the data.If using the IE browser,the data is normal(no space appear).

What is the cause?

Viewing all 8066 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>