Hi support
How do I exit Wavelink TE on CK3x device
Hi support
How do I exit Wavelink TE on CK3x device
One of our customers has as problem with the default functionality on a Datalogic Skorpio X3. The problem is shown on input fields. First, they type in a long string (in this example "9" is typed in several times). After that, they go back and and type several times "5", so they and up with "55559999" and with the cursor behind the last "5". After that, they want to press Enter and only have "5555" as the input result. But this won't work, because "55559999" is send as the result. According to the customer, this kind of functionality was possible on their old Datalogic Memor devices running the discontinued DL-TCL-NET software. So the question is how to get the same kind of functionality or workaround the problem.
I've been having some occasional trouble with the Wavelink Industrial Browser on some Datalogic Falcon X3s. (Both the Falcon X3 and Falcon X3+)
The IB shows the web page correctly, but when a scan is attempted, it seems like it reads the barcode (IE, the laser turns off), but there is no confirmation beep, and the data is not returned to the input box on the screen.
I've already confirmed that the scanning functionality works fine outside of Wavelink. Dropping back to Windows, they can scan text to Notes just fine.
I found this article in the knowledge base, but these settings don't seem to have made a difference.
Scanner wont input data on CI70 Device Using TelnetCE.
Anyone else run into this issue before?
Hi all
i need to use DATALOGIC FALCON X3 connected to an As400 via 5250 emulator .. i don't understand how to configure keyboard key (not virtual keyboard) so that i can emulate "ENTER" and "Exit fields" keys tipical for As400
Thanks in advance
Function Keys not working on MC3190
How to make it works.
Hi All
I have previously only used Windows CE but we are looking at rolling out Android devices. We are using the Telnet Emulation App and was wondering the best way to copy the configuration so i can deploy it to other devices. Eg Font sizes, Host settings etc.
Hi,
we cannot get the F12 key to work using 5250 emulation with ZEBRA MC92N0 CE7.O. When we try to get F12 to work we get an @ symbol, so we added the key macro 0040:\E055 to swap for the F12 key.
Now when we try the @ symbol does not appear but F12 does not function either?
Any help would be much appreciated.
We are using Motorola VC5090(CE5.0) and MC3190(CE6.0) at warehouse, through Wavelink 7.3, we connected to end user Telnet SSH Server
We discover after a certain time, the packer who is currently working and using MC3190, the wavelink clients would "jump out" and the messages prompt shown "connection reset by peer", it cannot recover, it is need to relogin again. So, it got annoying and heavy complain on us
Under the same network, VC5090 is good and no disconnected problems. We go through the network packages by Wireshark and found the followings.
1) How can we avoid the messages jump out and disconnect which is "Connect reset by peer" at MC3190?
2) Can we setup on MC3190 to transmit the packages by SSHv2 just like VC5090
We got a long complain from end user, look forward for kindly technical expert to help us on this, really thank a lot.
Regards,
William
I need to replace a <GS> (group separator) when I scan a GS1-128 barcode by a "]" character. How can I do that using terminal config from Wavelink Industrial Browser?
We use the Wavelink TE to connect to a barcodesystem . The emulation serverlanguage is set to UTF8 to show some german characters correctly.
Now the developer of the barcodesystem created a menupoint where we have to send a F3 to get a list back. When hit the F3 key on the scanner I get a Ò character.
So the question is how to send the F3 ?
In a terminal from a PC / Mac it's working
Thanks for your help
Ronald
How can we disable the zoom on screen tap in web environment?
e.g. when a user taps on a input form field the screen zooms in. How do we stop the zoom from happening?
Waiting for newer version of the Wavelink Telnet CE for Datalogic X4 CE7 Devices (now only v7.3.308) , I noticed that the v7.3.299 is already installed on the X4. Is there any possibility to find somewhere the installation program of this version?
As with the Datalogic Skorpio X3 the newer v7.3.302 had problems at usage of Function keys but installing the older v7.3.299 the problem was fixed automatically , the same i believe for all problems I have with the Wavelink TE at Skorpio X4 . I think there are some problems with the only version, which displays the letters in wrong way at menus and makes different the display for some of the screens at client's menu. Unfortunately ,there is no other version in case for me to check and use at Skorpio X4 .
Hello all
My devices are running 24/ 7 / 365.
After around 2 days the answers and reactions of the device are slower as on the first day.
A "good scan" needs time , the comming new website also
After around 3 days most devices have no reaction - if they in sleep mode I did not get them back alive.
We found out - IE cache is full !
The switch inside TB - WEB Clear Cache and und WEB Clear Cookies have only on time a effect - at the start.
Our device running all time - stop the session and exit Wavelink isn´t allow for the workers.
MC 9190
- germany and englisch OS - 1.34 // 2.41 same .
- Wavelink 7.3.206 and 7.3.196 -> older same effect
any idea ?
Carsten
When trying to connect to an host the application stops and presents in dialog box error: Unfortunately, Terminal Emulation has stopped. In Velocity i get exactly the same, only shows: Unfortunately, Velocity has stopped.
I am able to connect using TN3270 or TN5250 emulation to an other host.
Only alternative telnet emulator that works is Glink (competitor's product)
But my warehouse WMS is the host i need to connect to.
This has never been an problem before on WindowsCE devices in MC9xxxx series of Symbol (later Motorola, now Zebra) with Wavelink software for over 20 years now.
Since Windows is or will go end of life for these type of devices, i need an working solution on Android based scanners.
Tested on MC92N0 (Kitkat 4.4.4) and also on an demo Zebra TC8000 (Kitkat 4.4.3) provided by my supplier but got exact same result/error.
I already made an support ticket here with Ivanti, and with Zebra support, without any succes to date.
Who knows maybe here reads this, and has the same problem, and even better, someone who has an solution or at least suggestions.
I've used:
WavelinkTE v2.0.18.4977 (newest to date)
Velocity 1.0 / 1.2 / 2.0 ( 2.0 is newest to date)
Hello,
Our warehouse logistics are handled through an internal ERP application ensuring a proper flow of the reception and distribution of auto parts.
For this purpose we use around 110 mobile terminals with barcode scanners (RF Guns) of which 50 are deployed in the central warehouse.
The models used are:
Motorola MC2100
Datalogic Falcon X3
Datalogic Skorpio
In the central warehouse we are currently using 50 Motorola MC2100 scanners with Windows CE 6.0 operating system. As an emulator we are using Wavelink Corporation’s Telnet version 7.3.63 for Motorola MC2100 terminals.
Lately, the following problem began to manifest itself:
On a daily basis every Motorola MC2100 device suffers one or more unexplainable telnet session blocks.
When this happens, the terminal cannot interact with the application any more, the keyboard stops working and after a few minutes the display shows the "disconnected session" message. The terminal’s log doesn’t record any loss of connection to the access point.
The Access Points are all newly acquired from Motorola in order to ensure maximum compatibility between them and the mobile terminals.
Our question is:
To what extent the Telnet emulator may influence these session blocks, taking into account the following:
1. Telnet version
2. Certain parameters of the telnet configuration
3. “Avalanche Enable” configuration – we are using the Avalanche platform version 5.3.0.572 to manage our terminals
4. Having a large number of sessions (high load) on an Access Point.
Can you please help us with any idea in tackling this problem? Is there a log monitoring tool that can help us to identify the cause of these problems?
The situation is very critical and this seriously influences the process of delivery and reception of goods.
Thank you,
Florian Baloi
Hello,
I'm having problems with a Motorla scanner and Wavelink.
Everything (i need) that is configured in Emulation Parameters works, but the only thing that does not work is a "return" on barcode scan (Scan Handler).
My Wavelink version is TelnetCE 7.2.00 and i have a licence for VTHP.
I have also tried to use A(0)[A\\0D] but that does not work either.
The manual found on this page does not help either:
https://community.landesk.com/support/docs/29959
Is this a Wavelink version problem? Or am i doing something else wrong?
Scan Terminator is also \0D:
I have re-installed the Wavelink software on the Scanner, but that didn't help either.
Does anyone have any idea that i'm doing wrong?
The scanner is a Motorola MC9090 with WIndows Mobile 5.1
Thanks in advance!
Greetings,
Zarko
I've been having some occasional trouble with the Wavelink Industrial Browser on some Datalogic Falcon X3s. (Both the Falcon X3 and Falcon X3+)
The IB shows the web page correctly, but when a scan is attempted, it seems like it reads the barcode (IE, the laser turns off), but there is no confirmation beep, and the data is not returned to the input box on the screen.
I've already confirmed that the scanning functionality works fine outside of Wavelink. Dropping back to Windows, they can scan text to Notes just fine.
I found this article in the knowledge base, but these settings don't seem to have made a difference.
Scanner wont input data on CI70 Device Using TelnetCE.
Anyone else run into this issue before?
I've noticed that while going through and setting up a Host profile using the Wave link Configurator that it does not seem possible to add more than one ConnectPro server in a single Host Config.
Our current deployment utilizes two term-proxies (Windows CE/Mobile); how is it possible to get this done using the online tool for the new Android devices (92N0)?
Obviously configuring each client separately is not a solution (the TE client itself allows this).
Also, is there any possibility of making this configuration tool available in an offline desktop version?
Thanks
Hello, I try to activate a license TelnetCE on Motoral device via Lisence Server.
My steps:
1. I installed Licence Server on computer and then I added licences.
2. I installed a client on Motorola device with license server settings as :146.212.32.15:1820
3. When I launch a terminal, it stucks in atteption to connect server.
The version 7.3 matched for both: server lisence and version of client.
In log file I see connection log:
+06155066 2: No "TelnetCE 7.3 IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE 7.3 IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 0
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST" licenses available for MAC Address 0023685F9E6B, Site ID 0
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST/WEB" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE 7.3 VT/IBMHOST/WEB" licenses available for MAC Address 0023685F9E6B, Site ID 0
+06155066 2: No "TelnetCE Maintenance" licenses available for MAC Address 0023685F9E6B, Site ID 831
+06155066 2: No "TelnetCE Maintenance" licenses available for MAC Address 0023685F9E6B, Site ID 0
It means, the terminal can connect to server.
Status list:
What does unlicensed devices mean? Those devices can not get a license.