Can scaning with MC92N0 include Vibration?

$
0
0

Is there a TelnetCE 7.3.x CE7 Script command for MC92N0 to include Vibration with a scan beep? This can be triggered by DataWedge as per the user guide.


Macros

$
0
0

Hi,

 

I need help on the below case .

 

We are trying to map 2 keys

 

F10 & F11

 

F10 should be mapped to PC equivalent of Ctrl + F10, and F11 should be mapped to PC equivalent of Ctrl + F11

 

I have tried the key mapping config -

 

4400:\6700

 

And

 

5400:\5E00

 

We are using TelnetCE vers 7.3.252 and Windows Embedded C7

 

Thank you

 

 

 

keyboard custom and keycodes

$
0
0

We have a TC8000 and Wavelink TE 7.3 - all we want to do is add a custom keyboard one for alpha and one for numbers - what is the keyboard switching code? Has anyone actually done this and have it working? thanks

Scan Handler (Enter after barcode scan) not working

$
0
0

Hello,

 

I'm having problems with a Motorla scanner and Wavelink.

Everything (i need) that is configured in Emulation Parameters works, but the only thing that does not work is a "return" on barcode scan (Scan Handler).

My Wavelink version is TelnetCE 7.2.00 and i have a licence for VTHP.

 

29-1-2015 12-08-22.jpg

 

I have also tried to use A(0)[A\\0D] but that does not work either.

 

29-1-2015 12-43-29.jpg

The manual found on this page does not help either:

https://community.landesk.com/support/docs/29959

 

Is this a Wavelink version problem? Or am i doing something else wrong?

 

Scan Terminator is also \0D:

 

29-1-2015 12-46-31.jpg

 

I have re-installed the Wavelink software on the Scanner, but that didn't help either.

 

Does anyone have any idea that i'm doing wrong?

 

The scanner is a Motorola MC9090 with WIndows Mobile 5.1

 

Thanks in advance!

 

Greetings,

 

Zarko

Why does the IOS not read itf

$
0
0

I have downloaded the app, which comes up as an unlicensed version. No setup for decoders. I need ITF enabled. How do I license it and will this solve the problem?  

how do i install a wavelink licence onto a scanner?

$
0
0

how do i install a wavelink licence onto a scanner?

Function keys with WT41N0 Telnet CE 7.3.192 VT220 emulation

$
0
0

Hi i'm having difficulties using function keys with Motorola WT41N0 Telnet CE 7.3.192 and VT200 emulation. Random charachtes or error message key not recognized is diplayed if i'm trying to use Function keys (F1; F2 etc.) Any ideas?

Problem with VT100 session - function key

$
0
0

In VT100 session you must press the ENTER key after a function key.  it's possible automatically send the ENTER key after a function key?

My device is a WinCE MC9200 handheld Mobile Computer.

 

Thanks.


Export configuration from Android Telnet Emulation client

$
0
0

Hi All

I have previously only used Windows CE but we are looking at rolling out Android devices. We are using the Telnet Emulation App and was wondering the best way to copy the configuration so i can deploy it to other devices. Eg Font sizes, Host settings etc.

How to take over a Wavelink configuration

$
0
0

Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via Active Sync) to another MC9100 but that don't work. If I looked in the Termcfg.bin I didn't find my configuration profile.

In which file is the configured profile from my Wavelink Telnet (Version 7.3.40) saved?

 

Another possibiltiy to take over the profile should be the Wavelink TelnetCE Configuration Utility but I can't find a download. Is this software only available for

maintenance agreement?

 

I hope you can help me :-)

Thanky You

 

Olaf

The taskbar is not visible in TelnetCE, even though I'm not hiding anything in the options tab. How can I get it back, so I cen get into the config menus

$
0
0


I'm using TelnetCE 7.3 with app center.  When I go into TelnetCE, I lose the taskbar which contained the config menus.

So I can't change config or even exit the program.  I'm force to cold boot to exit TelnetCE.  I'm do not have any

options in the 'options' tab checked, so nothing should be hidden.  How can I get it back?

Does WavelinkTE for android not support UTF8?

$
0
0

I am suing WavelinkTE for android

I cannot find ufr8 encoding.

How to solve it?

Error scanning a barcode for "Q00012" on Honeywell 99EX barcode scanner

$
0
0

Scanning a quantity bardcode for "Q00012" and  get a loud beep and scanner displays  738197538.   Using code 39 symbology.  Scanned the barcode using honeywell scanwedge software and its reads as "Q00012".   No other quantities have given us any issues.  We just recently upgraded to these scanners after using Dolphin 7400's for about 10 years.  Logged in with old scanner and it reads barcode just fine, but uses a different terminal emulation software.   Issue has to be with Wavelink, any idea's would be greatly appreciated.  Using Wavelink VT terminal emulation.

How to enable keyclicks in Android TE 2.0

$
0
0

How to enable keyclicks in Android TE 2.0 *Please don't suggest Velocity due to the context bar not fitting screens info

Remap function keys

$
0
0

Hi,

 

I'm trying to remap F1 to [ALT][F1] with the Wavelink TE Android's version for a Panasonic FZ-A1, as far as I know F1 stands for 3B00 , but I don't know wich scape secunce stands for [ALT] key, and hoy to concatenate it with the [F1].

 

¿Does any of you has an idea about how to solve it?

 

 

Thanks in advace,


What's the difference between the two purchasable options?

$
0
0

The two options are Terminal Emulation 2 in 1 TN Client  vs Terminal Emulation 4 in 1 Client. I'm trying to purchase Wavelink for the MC9500 series.

TelnetCE Autologin Command Prompt not excecuted (return/enter not sent to the host)

$
0
0

Problem with Autologin feature which will stop and wait for user to press ENTER instead of executing command automatically.

 

Setup:

Wavelink TelnetCE - Host Profile - Autologin:

Name Prompt: "login:"

Name: "myuser1"

Password Prompt: "password:"

Password: "mypwd" (displayed as "*****"

Command Prompt: "domain:"

Command: "mydomain.com"

 

Result of connection test:

Autlogin correctly sets and executes login and password but for domain prompt only presets value "mydomain.com" and does not execute it (waits for user to press ENTER).

 

Expected result:

Return/ENTER is sent to host to execute the command.

 

Remarks:

The same problem occurs also for standard command (e.g. D:\MyApp\start.bat) when domain prompt is removed in the server setup.

 

Enviro:

Host: Windows Server 2008 R2 64bit, Georgia Softworks Telnet Server 8.05

Client: Motorola MC9190G, Windows Mobile 6.5, Wavelink TelnetCE 7.3.237 (latest available)

 

Thank you,

Michal

Configuration Function Key F5 and F6 to TE VT220

$
0
0

Anyone knowthe configuration ofkeysF5andF6function inVT220emulation?


I have a customer usgin SAP VT220 emulation.

 

 

I triedthe settings below,butit did not work

F5 - 3F00:\3F00\000D

F6 - 4000:\0336\000D

 


Cyrrilic in Telnet CE Version 7.3.172

$
0
0

Hi!

We are using Motorolа Mc9190 terminals and  Wavelink Telnet CE Version 7.3.172 with following settings:

Emulation: VT220

Display language:  Russian - KOI8

Server Language: UTF-8

 

 

 

 

Displaying of russian symbols are fine but

If we enter russian characters by keyboard or by scanning barcodes we get symbols ?????

wavelink_no_russian.jpg

Is there any way to solve this issue?

WT4100 StartUp Problem

$
0
0

We just got new WT4100 from our distributor. Using with TelnetCE at version 7.3.144 (5250 and WT100 sessions). The problem we are facing is that after boot an aoutostrup applican  (WT41NOSTARTUP) is automatically launced by the system. This application is undesired and in conflict wiith the one (TelnetCE) we configured to startup.

 

The main question is how to remove the WT41NOSTARTUP application from startup. We already checked that the application is not defined into the startup folder. Also can see that the WT41NOSTARTUP has a shortcut onto the desktop. If we remove from the desktop at next boot it reappers.

 