Quantcast
Channel: Ivanti User Community : Popular Discussions - Terminal Emulation (Powered by Wavelink)
Browsing all 8066 articles
Browse latest View live

Image may be NSFW.
Clik here to view.

How can you avoid this?

Using our current WT4090 Wavelink config files, the WT41N0 asks the user to reboot the terminal to change the taskbar state.We don’t want the users to make this choice.  If they choose no, then...

View Article


Escape Sequence for Beep

I have a client that uses MC3190 with SAP, in emulator VT100, they need at certain times cause the collector to beep, I remember that there was a Escape sequence codes the emulator understood that...

View Article


Hardware trigger becomes disabled on Intermec CK3X on WLTE exit.

http://community.landesk.com/support/docs/28233 describes the issues exactly, but upon exit of Wavelink TE the scan trigger becomes disabled again requiring RE-enabling. I may be doing something...

View Article

telnet server could not log you in using ntlm authentication

I am getting this message and Win7 immediately closes the session. anything that I should do on Win7 telnet server side?It's the same all for windows mobile 6.5 and android clients. thanks

View Article

barcode scan error

Wavelink TE Version 7.3.135 on Honeywell Dolphin 7600 Some product barcodes do not scan correctly in the Wavelink Telnet session. For Example;  We have a Product Code RN2944 for which we use Free 3 of...

View Article


Programmatically Editing Emulation Parameters

What is the best method for editing the Emulation Parameters that are stored in the TERMCFG.bin file on the device manually? In other words, I would like to be able to dynamically edit a few emulation...

View Article

How to have loudly sound on MC3190?

Hello,on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse we need to know how we can set correctly TelnetCE to have a very...

View Article

Strange characters on WEB emulation

Hello. Some time ago I had problems with Datalogic Elf and Telnet Web emulation version 7.2Some characters appears strange, for example:- accented a ("à") appears as "A" with an upper wave (the...

View Article


How to take over a Wavelink configuration

Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via...

View Article


WT4100 StartUp Problem

We just got new WT4100 from our distributor. Using with TelnetCE at version 7.3.144 (5250 and WT100 sessions). The problem we are facing is that after boot an aoutostrup applican  (WT41NOSTARTUP) is...

View Article

Motorola MC9090G, CE5.0 OS: 1.35.0000 Persistance TE Configuration

Hello,I have a clientwhohas 35unitsMC9090Gterminalandneeds to establisha quick waytosetall terminals,but without usingprograms installed onPC.Itry to make acopy-paste.This OS version incorporates...

View Article

Wavelink TelnetCE 73197 Display Language - UTF8

Hello.I have Motorola MC3190 and TelnetCE 73197. I need select UTF8 in "Display Language". It is demand for correct display Russian language in the programm. I do not see UTF8 in list "Display...

View Article

TelnetCE Host Type WEB is not Licensed on MC9190?

Hi Friends!We have 5pc Motorola Symbol MC9190-G on Windows CE 6.We want to use TelnetCE 7.3.146 or 7.0.94 (that installed) as Industrial Browser. But if I use Host Type "WEB", Demo-License message...

View Article


TelnetCE for MC3190-S

Hello Community, I've a bunch of MC3190-S (not guns). Please suggest me where to buy Wavelink TelnetCE for this terminal.Directly from Motorola or from Wavelink?I've found document on motorola website...

View Article

MC92N0 CE7.0 - TE ver 7.3.196 Keypad Problems

Hi, I have a problem using the TE 7.3.196 on a MC92N0 CE7 OEM version 00.33.06.When I install the client for the first time the keypad works good, ie pressing the combo BLUE + ENTER the client produce...

View Article


Using the wavelink browser to read the EAN128 barcode,the data is not right...

Using the wavelink browser to read the EAN128 barcode,the data is not right that some space appear. Using the IE browser,no space appear. How to resolve the problem?

View Article

Motorola MC9190 Chinese letters in Wavelink 5555 emulation

We use on a MC9190 the wavelink TelnetCE version 7.0.147. For our chinese colleagues I we use the emulation 5555-B01 to display also chinese letters.Our problem is, that only a part of the chinese...

View Article


Datalogic Falcon X3 - TelnetCE Program Diagnostics Scan Test - no data showing

When I test the scanner from within windows the barcode data scanned displays correctly however when I use the TelnetCE Program Diagnostics Scan Test no data is displayed. Has anyone any ideas please?

View Article

Does Wavelink TelnetCE support Chinese (We are using a Motorola MC9190-G gun)?

Does Wavelink TelnetCE support Chinese (We are using a Motorola MC9190-G gun)? When We look for Chinese in the localization configuration, We do not find the Chinese option. ¿Should our MC9190-G have a...

View Article

user password in one barcode

HiDo you think that's possible to identifiy user and password in one barcode?I tried to create user  TAB password, it doesnt't match.(user0x09password).Terminal emulation Wavelink TelnetcE 5250Thank...

View Article
Browsing all 8066 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>