The taskbar is not visible in TelnetCE, even though I'm not hiding anything...
I'm using TelnetCE 7.3 with app center. When I go into TelnetCE, I lose the taskbar which contained the config menus.So I can't change config or even exit the program. I'm force to cold boot to exit...
View Article5250 emulator issues with WT41N0 devices
We have purchased several WT41N0 devices in the last 4 months. It seems like ALL of them are having issues with the telnet client in some way or another. The user will be in the middle of a telnet...
View ArticleHow to have loudly sound on MC3190?
Hello,on MC3190 when we use Telnet CE ( any version) the level of the sound is not enough loud to be hear by a end user in the warehouse we need to know how we can set correctly TelnetCE to have a very...
View ArticleVT100 DISABLE SCANNER
Hello, I need to know the string that a VT100 server have to send to a Datalogic Terminal using TelnetCE to "DISABLE" and "ENABLE" the scanner device I need, in case of error, that the Datalogic...
View ArticleHow I replace GS (Group Separator) from GS1-128 by "]" character ?
I need to replace a <GS> (group separator) when I scan a GS1-128 barcode by a "]" character. How can I do that using terminal config from Wavelink Industrial Browser?
View ArticleDisable Scanner Selection Windows on TelnetCE Startup
Anyone know how I can do this? When I Start TelnetCE a windows comes up "Scanner Selection" Do you want to use the scanner "Bluetooth SSI Scanner Driver" instead of the Default scanner "External...
View ArticleWhat VT escape sequences are supported?
Hi there, We have a legacy custom-written telnet server to which several MC9090 devices running Wavelink TE are connecting to. We need to update this server to support configuring the scanners on the...
View ArticleWT41N0 TE Client SSH connection error: disconnected: no supported...
The attached screenshot shows the SSH Client Fatal Error message from the title of this question.
View ArticleTelnet emulator session block
Hello, Our warehouse logistics are handled through an internal ERP application ensuring a proper flow of the reception and distribution of auto parts.For this purpose we use around 110 mobile terminals...
View Articlecookies not setting on Windows Mobile Embedded 6.5
I've got two Motola MC 9190 scanners. Set up as follows. Scanner 1 - Windows CE 5.0, Wavelink Telnet CE 7.0.94 - Web emulation profile.Scanner 2 - Windows Mobile 6.5, Wavelink Telnet CE 7.0.147 - Web...
View ArticleWindows Embedded 8.1
Are there any plans to support Windows Embedded 8.1 Handheld with Telnet and Industrial Browser?
View ArticleWavelink TE don't reconize a few letters.
Hi. Our customer are using an Intermec CN51 WM unit whit Wavelink Terminal Emulator.In Norway the letters ÆØÅ is used on on-screen qwerty, when in TE they need to type a name for example Norwegian name...
View ArticleCyrrilic in Telnet CE Version 7.3.172
Hi!We are using Motorolа Mc9190 terminals and Wavelink Telnet CE Version 7.3.172 with following settings:Emulation: VT220Display language: Russian - KOI8 Server Language: UTF-8 Displaying of...
View ArticleWavelink TE for the Universal Android Mobile Device on a MC67 device. The...
Hello.I'm trying out Wavelink TE for the Universal Android Mobile Device on a MC67 device running Android.It is emulating a VT220 and is generally working wonderful.The only downside is the device...
View ArticleHow to take over a Wavelink configuration
Hello, I have some Motorola MC9100 and I'd like to take over the configuration from one device to another device. I heard that I could copy the Termcfg.bin from the application\wavelink folder (via...
View ArticleHow do I configure the ESC and yes and no buttons on Symbol MT2090 running...
I have a Symbol MT2090 and installed the Wavelink Telnet CE 7395 client. I connect to the terminal session ok but have found that the ESC key does not work to go back. I also need to configure Yes/No...
View ArticleCan you add screen-specific Key Macros using the Screen Reformatter?
I am very familiar with both Key Macros within the TelnetCE Emulation Parameters and the Screen Reformatter and I am curious if there is any ability to have Key Macros that are designed for a specific...
View ArticleHow to read TID + EPC + RESERVED + USER MEMORY in the same time?
Hi... I'm sorry for to opened in the last days two wrong request, and I removed them, but I studied a lot the problem I have and now I found what I would to ask.When I use the Wavelink Telnet CE with...
View ArticleIs there a way to emulate page up and page down for motorola MC3190 ?
Good morning,is there a possibility to scroll up and down my screen when i'm using a wavelink 5250 emulation ? I can't use any combination of keys or the up/down specific keys. Can someone help me...
View ArticleScan continuously on Telnet CE 7.3
Hi, An application requires the that a scanner scan beam be activated continuously.The device is going to be mounted on a stand and users will pass bar codes in front of it.Does the Terminal Emulation...
View Article